Jinan Dibaier Environmental Protection Materials Co., Ltd
Fire Resistant PU Metal Sandwich Panel
Fire Resistant PU Metal Sandwich Panel suppliers
Fire Resistant PU Metal Sandwich Panel factory
Fire Resistant PU Metal Sandwich Panel best

Fire Resistant PU Metal Sandwich Panel

Classification of the combustion performance of sandwich panels Grade standard: The fire performance grade of the main circuit board must be strictly in accordance with the core standard GB 8624 2012 appearing in the fire performance grades of building materials and goods, and the categories are...

Send Inquiry
Description

Classification of the combustion performance of sandwich panels

 

Grade standard: The fire performance grade of the main circuit board must be strictly in accordance with the core standard GB 8624 2012 appearing in the fire performance grades of building materials and goods, and the categories are A, B1, B2. Their residual heat moves to almost non-flammable, flammable, combustible and flammable materials at a rather high level.

My company offers a range of flammability grades to customers, except for one type of flammable flame, as follows:

01
 

Grade A (Non-combustible core)

Refractory solids that are almost non-combustible under standard conditions, with requirements for fire resistance stability, suitable for police traction in critical areas, data centers, and central computer rooms.

 
02
 

Grade B1

It has a sharp fire-extinguishing effect, and open flames can burn briefly in air or hot conditions. Even in a fire, it rarely spreads. Once the stove is removed, the flame will stop burning immediately. For mixed commercial complexes, industrial factories, exterior walls, etc.

 
03
 

B2 (Burning point)

Only at the main tearing point. An increase in fire risk or an increase in heat in the air can lead to hotter fires. Only in non-core areas with basic fire protection requirements, such as temporarily built halls, storage rooms and additional storage Spaces, is it recommended to use with caution.

product-556-454
Production process
product-462-460
Pretreatment of aluminum alloy plates
The Fire resistant PU metal sandwich pane produced by our company selects high-quality aluminum alloy plates as the base material. Firstly, its surface is deeply cleaned to remove impurities and stains; Then, deaeration treatment is carried out to form a dense oxide film on the surface of the aluminum plate, enhancing its corrosion resistance and subsequent adhesion.
product-439-433
Core material processing
Thoroughly mix the flame retardant additive with PE plastic to ensure uniform distribution of fire resistance performance. Subsequently, the mixed materials are melted and extruded through an extruder to form a uniform plastic intermediate layer.
product-324-323
Adhesive coating and lamination
Strictly follow the adhesive usage instructions to prepare the appropriate proportion of adhesive liquid, and use professional tools to evenly apply it to the surface of the aluminum alloy plate and the PE plastic layer. Then, the two are precisely bonded together and uniform pressure is applied. They are placed in a preheated press and subjected to hot pressing at a specific temperature and pressure to ensure that each layer is closely combined.
product-490-485
Fireproof coating treatment
According to the product design requirements, mix the fireproof coating with the solvent in proportion, and apply it evenly on the surface of the aluminum-plastic panel with a brush or spray gun to further enhance the overall fire resistance performance.

 

The application scenarios of sandwich panels
 

Industrial parks

Firewalls, walls and interior decoration in factories such as electronics and chemical industries comply with the requirements of fire protection standards. All types of factories meet the requirements of 5,016 Thai baht. It can also be used on the walls of flammable bearings and roofs to reduce risks.

Business field

Mainly applied in interior decoration, architectural decoration, hotels, trading stations, etc. The fire resistance performance of these refractory materials complies with the regulations of fire limits, such as fire resistance limits and smoke poisoning. Lighters can also play a significant role in the damp conditions of garages, high fire protection requirements, and the stability of the lighter system.

Public facilities

In places such as schools and hospitals, the fire safety and hygiene of stoves are particularly important. They are not only crucial for life safety but also for people's comfort. Monitoring reports related to the arson call for transportation are available and can provide a complete report on the monitoring results, which will help the project carry out arson on the stands and prepare for safe sales.

Other motives

It is also applicable to the renovation and refurbishment of old buildings to enhance the overall firepower and appearance of the buildings. The shield and patterns comply with fire prevention regulations, and the decoration is pure. Even fire-resistant refractory materials can meet the requirements of special environments.

Customization and service of sandwich panels

 

 

1
product-1-1

Customized services

We can provide customized solutions based on the different project requirements of our clients. Such as adjusting the thickness of the sheet, choosing specific aluminum alloy materials, customizing the surface coating color and treatment process, and developing special specifications and dimensions, etc.

2
product-1-1

Pre-sale service

Our professional team provides customers with detailed product consultation. Based on the characteristics and requirements of the project, we recommend the most suitable product models and specifications. Free samples are provided to facilitate customers' intuitive understanding of product performance and quality.

3
product-1-1

During-sale service

Efficiently handle orders and promptly feedback production progress; Provide professional transportation solution suggestions to ensure the safe and punctual delivery of products to the project site.

4
product-1-1

After-sales Service

Our company's Fire resistant PU metal sandwich pane offers a 5-year quality guarantee period. During the warranty period, if there are any quality problems with the product, we will respond promptly and provide free repair or replacement services. At the same time, provide customers with product usage training and technical support, and answer any questions they may have during the usage process.

Maintenance and upkeep of sandwich panels
 

Daily cleaning

For fireproof aluminum-plastic composite panels indoors, a soft cloth dipped in clean water or neutral detergent can be used to gently wipe the surface to remove dust and stains. For outdoor panels, high-pressure water guns can be used for regular rinsing. During rinsing, the water pressure should not be too high to avoid damaging the panel coating.

Avoid collisions

During daily use, sharp objects should be prevented from colliding with the surface of the board to avoid scratches, depressions and other damages to the panel. If damage occurs accidentally, it should be repaired in time. Small scratches can be treated with special repair agents, while large damage requires the replacement of the board.

 

Regular inspection

Regularly inspect the installation and fixation of the panels, as well as the sealant at the joints. If problems such as loose screws or cracked sealant are found, they should be dealt with promptly to ensure the safe use and stable performance of the panels. It is generally recommended to have a check-up every six months.

 

Special case handling

If the surface of the board is stained with oil, chemicals or other stubborn stains that are difficult to clean, a dedicated cleaner should be used promptly for treatment to prevent the stains from adhering to the surface for a long time and causing corrosion to the panel. In the event of special circumstances such as fire or earthquake, professionals should be invited to conduct a comprehensive inspection of the boards to assess whether their performance has been affected. If necessary, they should be replaced.

FAQ

Q: What are the differences between B1 grade and A grade fire protection?

A: Grade A is non-combustible materials such as rock wool, but PU has better thermal insulation performance. Grade B1 has met the needs of most non-high-risk scenarios, and after modification, its flame retardancy is close to Grade A.

Q: Can it be used in open flame environments such as kitchens?

A: Fireproof rock wool boards should be used in the direct open flame area of the kitchen. This type can be used for adjacent partition walls, and a distance of ≥1.5m should be maintained.

Q: How to clean a dirty sandwich panel?

A: Wipe with clean water or neutral detergent. Do not use strong acids or alkalis.

Q: Will the insulation performance of fireproof PU boards decline due to flame-retardant treatment? Which is more suitable for cold storage, rock wool board or rock wool board?

A: Even after flame-retardant treatment, the insulation performance of fireproof PU boards will not decline. Its thermal conductivity can still be as low as ≤0.024W/(m · K), and compared with most traditional insulation materials, its insulation performance has significant advantages.

Q: Will the fire resistance of the board decline after years of use?

A: The flame retardant has strong stability. The flame retardant effect will decline by no more than 5% within 15 years of normal use. Aging test reports can be provided.

 

 

 

 

 

 

Hot Tags: fire resistant pu metal sandwich panel, China fire resistant pu metal sandwich panel manufactures, suppliers, factory

Inquiry
goTop

(0/10)

clearall